| Construction | 1 to 7 (Low-Rise) | 8 - 20 Stories | 21 - 50 Stories | 51+ | ||
| ONE OF THE FOLLOWING (3 options): | ONE OF THE FOLLOWING (2 options): | |||||
| Battery Smoke Detectors | ||||||
| Fire Resistive | - Central Station Alarm System or | - Central Station Alarm System | Decline | |||
| Illuminated Exit Signs (waived if emergency lighting installed)* | - Manual Pull Alarm or | - Manual Pull AND EITHER a 24 Hour Doorman OR an | ||||
| ISO Class -6 | - 24 Hour Doorman/Watchman AND EITHER | Annunciator Panel | ||||
| Emergency Lighting* (required in all buildings with more than 12 units or more than 3 floors**) | an intercom system OR an annunciator panel | |||||
| Two Exits Per Floor (bldgs w/ 5+ flrs) | And these requirments: | And these requirments: | ||||
| Modified Fire Resistive | Standpipe or Partial Sprinklered | Standpipe or Partial Sprinklered | ||||
| ISO Class - 5 | 2 Exits Per Floor or Enclosed Stairwell* | If built after 1999 - Fully sprinklered | If built after 1999 - Fully sprinklered | |||
| (blgs w/ 1-4 flrs & no more than 8 units/flr) | Bat. or H/W Smoke Detectors | |||||
| Bat. or H/W Smoke Detectors | Emergency Plan | |||||
| *(Exception: Garden Apts or units with Direct exit to the outside or ) | Emergency Lighting | Emergency Lighting | ||||
| **(Unless every unit has direct exit to the outside of the bldg or no interior hallways; if more than 12 units with fire walls, we can consider for referral) | Two Exits Per Floor | Enclosed Stairwells | ||||
| Two Exits Per Floor | ||||||
| ONE OF THE FOLLOWING (3 options): | ONE OF THE FOLLOWING (2 options): | |||||
| Battery Smoke Detectors | ||||||
| Non-Combustible | - Central Station Alarm System or | - Central Station Alarm System | ||||
| Illuminated Exit Signs (waived if emergency lighting installed)* | - Manual Pull Alarm or | - Manual Pull AND EITHER a 24 Hour Doorman OR an | ||||
| ISO Class - 4 | - 24 Hour Doorman/Watchman AND EITHER | Annunciator Panel | ||||
| Emergency Lighting* (required in all buildings with more than 12 units or more than 3 floors**) | an intercom system OR an annunciator panel | And these requirments: | ||||
| Standpipe or Partial Sprinklered | ||||||
| Two Exits Per Floor (bldgs w/ 5+ flrs) | And these requirments: | If built after 1999 - Fully sprinklered | ||||
| Standpipe or Partial Sprinklered | Bat. or H/W Smoke Detectors | |||||
| 2 Exits Per Floor or Enclosed Stairwell* | If built after 1999 - Fully sprinklered | Emergency Plan | ||||
| (blgs w/ 1-4 flrs & no more than 8 units/flr) | Emergency Lighting | |||||
| Bat. or H/W Smoke Detectors | Enclosed Stairwells | |||||
| *(Exception: Garden Apts or units with direct exit to the outside or ) | Emergency Lighting | Two Exits Per Floor | ||||
| **(Unless every unit has direct exit to the outside of the bldg or no interior hallways; if more than 12 units with fire walls, we can consider for referral) | Two Exits Per Floor | Concrete Stairwells with Pressurized Stairwell Doors | ||||
| Battery Smoke Detectors | ||||||
| Joisted Masonry | Decline | Decline | Decline | |||
| Illuminated Exit Signs (waived if emergency lighting installed)* | ||||||
| ISO Class - 2 | Emergency Lighting* (required in all buildings with more than 12 units or more than 3 floors**) | |||||
| Two Exits Per Floor (bldgs w/ 5+ flrs) | ||||||
| 2 Exits Per Floor or Enclosed Stairwell* | ||||||
| (blgs w/ 1-4 flrs & no more than 8 units/flr) | ||||||
| *(Exception: Garden Apts or units with Direct exit to the outside or ) | ||||||
| **(Unless every unit has direct exit to the outside of the bldg or no interior hallways; if more than 12 units with fire walls, we can consider for referral) | ||||||
| Frame | Battery Smoke Detectors | Decline | Decline | Decline | ||
| Illuminated Exit Signs (waived if emergency lighting installed)* | ||||||
| ISO Class - 1 | ||||||
| Emergency Lighting* (required in all buildings with more than 12 units or more than 3 floors**) | ||||||
| Two Exits Per Floor (bldgs w/ 5+ flrs) | ||||||
| 2 Exits Per Floor or Enclosed Stairwell* | ||||||
| (blgs w/ 1-4 flrs & no more than 8 units/flr) | ||||||
| *(Exception: Garden Apts or units with Direct exit to the outside or ) | ||||||
| **(Unless every unit has direct exit to the outside of the bldg or no interior hallways; if more than 12 units with fire walls, we can consider for referral) | ||||||
| *Garden Apartments = 2 story apartment | ||||||
| If more than 12 units with fire walls - fire wall must extend through roof (parapet). | ||||||