Construction 1 to 7 (Low-Rise) 8 - 20 Stories 21 - 50 Stories 51+    
     ONE OF THE FOLLOWING (3 options): ONE OF THE FOLLOWING (2 options):    
  Battery Smoke Detectors        
Fire Resistive   - Central Station Alarm System or           - Central Station Alarm System Decline  
  Illuminated Exit Signs (waived if emergency lighting installed)* - Manual Pull Alarm or            - Manual Pull AND EITHER a 24 Hour Doorman OR an    
ISO Class -6   - 24 Hour Doorman/Watchman AND EITHER                  Annunciator Panel    
  Emergency Lighting* (required in all buildings with more than 12 units or more than 3 floors**)    an intercom system OR an annunciator panel      
           
  Two Exits Per Floor (bldgs w/ 5+ flrs) And these requirments: And these requirments:    
Modified Fire Resistive   Standpipe or Partial Sprinklered Standpipe or Partial Sprinklered    
ISO Class - 5 2 Exits Per Floor or Enclosed Stairwell* If built after 1999 - Fully sprinklered If built after 1999 - Fully sprinklered    
  (blgs w/ 1-4 flrs & no more than 8 units/flr)   Bat. or H/W Smoke Detectors    
    Bat. or H/W Smoke Detectors Emergency Plan    
   *(Exception: Garden Apts or units with Direct exit to the outside or )  Emergency Lighting Emergency Lighting    
  **(Unless every unit has direct exit to the outside of the bldg or no interior hallways; if more than 12 units with fire walls, we can consider for referral) Two Exits Per Floor Enclosed Stairwells    
    Two Exits Per Floor    
    ONE OF THE FOLLOWING (3 options): ONE OF THE FOLLOWING (2 options):    
  Battery Smoke Detectors        
Non-Combustible   - Central Station Alarm System or           - Central Station Alarm System    
  Illuminated Exit Signs (waived if emergency lighting installed)* - Manual Pull Alarm or            - Manual Pull AND EITHER a 24 Hour Doorman OR an    
ISO Class - 4   - 24 Hour Doorman/Watchman AND EITHER                  Annunciator Panel    
  Emergency Lighting* (required in all buildings with more than 12 units or more than 3 floors**)    an intercom system OR an annunciator panel And these requirments:    
      Standpipe or Partial Sprinklered    
  Two Exits Per Floor (bldgs w/ 5+ flrs) And these requirments: If built after 1999 - Fully sprinklered    
    Standpipe or Partial Sprinklered Bat. or H/W Smoke Detectors    
  2 Exits Per Floor or Enclosed Stairwell* If built after 1999 - Fully sprinklered Emergency Plan    
  (blgs w/ 1-4 flrs & no more than 8 units/flr)   Emergency Lighting    
    Bat. or H/W Smoke Detectors Enclosed Stairwells    
   *(Exception: Garden Apts or units with direct exit to the outside or )  Emergency Lighting Two Exits Per Floor    
  **(Unless every unit has direct exit to the outside of the bldg or no interior hallways; if more than 12 units with fire walls, we can consider for referral) Two Exits Per Floor Concrete Stairwells with Pressurized Stairwell Doors    
         
         
  Battery Smoke Detectors      
Joisted Masonry   Decline                                       Decline Decline
  Illuminated Exit Signs (waived if emergency lighting installed)*      
         
ISO Class - 2 Emergency Lighting* (required in all buildings with more than 12 units or more than 3 floors**)      
         
  Two Exits Per Floor (bldgs w/ 5+ flrs)      
         
  2 Exits Per Floor or Enclosed Stairwell*      
  (blgs w/ 1-4 flrs & no more than 8 units/flr)      
         
   *(Exception: Garden Apts or units with Direct exit to the outside or )      
  **(Unless every unit has direct exit to the outside of the bldg or no interior hallways; if more than 12 units with fire walls, we can consider for referral)      
       
         
Frame Battery Smoke Detectors Decline                                       Decline Decline
         
  Illuminated Exit Signs (waived if emergency lighting installed)*      
ISO Class - 1        
  Emergency Lighting* (required in all buildings with more than 12 units or more than 3 floors**)      
         
  Two Exits Per Floor (bldgs w/ 5+ flrs)      
         
  2 Exits Per Floor or Enclosed Stairwell*      
  (blgs w/ 1-4 flrs & no more than 8 units/flr)      
         
   *(Exception: Garden Apts or units with Direct exit to the outside or )      
  **(Unless every unit has direct exit to the outside of the bldg or no interior hallways; if more than 12 units with fire walls, we can consider for referral)      
       
*Garden Apartments = 2 story apartment
If more than 12 units with fire walls - fire wall must extend through roof (parapet).